Abstract in English: Graphene and conductive polymers had gain great deal of interest in various fields, such as in energy, environmental, and biomedical application, owing to their outstanding chemical and physical properties compared to conventional metal. Thus, in this study a reduced graphene oxide (rGO)-poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)-based electrode was fabricated via a simple two-step, physical drop-cast method followed by subsequent electrochemical reduction. Cyclic voltammetry (CV) was used to characterize the redox capability of the composite layer on the electrode surface. Electrochemical deposition of rGO-PEDOT:PSS composites with a 1:1 ratio gives the highest anodic peak current Ipa of 1.184 mA and the largest effective surface area of 12.9 mm2, compared to rGO alone electrodes (Ipa = 0.552 mA, A=12.9 mm2). The rGO-PEDOT:PSS composites were characterized by scanning electron microscopy (SEM), transmission electron microscope (TEM), RAMAN Spectroscopy, Fourier-transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD). SEM results show the composite to have an open edge with a rougher surface morphology compare to rGO alone and TEM implies PEDOT:PSS is encapsulated by rGO. RAMAN spectroscopy shows the D band/G band intensity ratio of the composite films was increased from 1.12 (GO-PEDOT-PSS) to 1.25 (rGO-PEDOT:PSS) after electrochemical reduction, suggesting reduction of defects in graphene. Furthermore, XRD shows that the interlayer distance of rGO was increased from 0.37?nm (for rGO film) to 0.47?nm for rGO-PEDOT-PSS, confirming the effective intercalation of PEDOT/PSS in between rGO layers. Finally, glucose biosensor with rGO-PEDOT:PSS as transducer was successfully fabricated, and the sensitivity, sensitivity per electrode area, and limit of detection were 2.03 �A/mM, 15.74 �A/mM cm2, and 0.08 �M, respectively. The results show rGO-PEDOT:PSS composite is an excellent precursor for the development of redox active transducer that can result in highly sensitive non-invasive glucose sensor. Keywords: graphene, reduced graphene oxide, cyclic voltammetry, PEDOT:PSS, glucose sensor
Degree Level: Master
Kullliyah: Kulliyyah of Engineering
Programme: Master of Science (Biotechnology Engineering).
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/4400
URL: https://lib.iium.edu.my/mom/services/mom/document/getFile/CGUtWJ3pdG2qLHtnE0VETBA43rfQNB1U20191014111158059
Appears in Collections:KOE Thesis

Files in This Item:
File Description SizeFormat 
t11100404667HabibahFarhana_SEC_24.pdf24 pages file1.14 MBAdobe PDFView/Open
t11100404667HabibahFarhana_SEC.pdf
  Restricted Access
Full text secured file4.11 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

10
checked on May 19, 2021

Download(s)

2
checked on May 19, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.