Title: Daylight penetration in Malaysian high-rise office buildings
Authors: Abu Nur Mohammad Shahriar
Subject: Daylighting -- Malaysia
Buildings -- Malaysia -- Environmental engineering
Interior lighting -- Malaysia
Architecture -- Environmental aspects -- Malaysia
Daylight
Year: 2006
Publisher: Kuala Lumpur : International Islamic University Malaysia, 2006
Abstract in English: In our natural environment, there is an abundance of daylight. Before the invention of electric lighting, it was a primary source of interior illuminance. However, in today’s office buildings, daylight is being underutilized and dependency on artificial lighting is very common. Daylight use can be an energy saving feature of a building by reducing demand for electric lighting. It is very difficult to provide adequate amount of daylight all through a side lit space. Therefore, the knowledge regarding depth of its penetration is important for its proper utilization. This requires detailed daylight analysis. Standard skies are a very important part of this analysis. Recently, sets of fifteen skies have been adopted by the CIE (Commission Internationale de L’eclairage) as standards for the entire globe. These have not yet been incorporated into daylight simulation software. In order to incorporate these standard skies, the study has analysed the depth of daylight and permanent supplementary artificial lighting for interiors (PSALI) in high-rise office under hot-humid climate of Peninsular Malaysia using an alternative method. The study used ‘Daylight Coefficient’ to perform daylight calculation. ‘Waldram Diagram’ has been used to calculate the visible sky needed for the daylight coefficient method. Two experiments were conducted to find the upper and lower limits of daylight penetration throughout the year. The lowest levels have been analysed to determine the limiting depth of daylight while the difference between the lowest and highest penetration was considered for PSALI. The research found the depth of daylight was 3 m and 3.5 m from an adjacent window considering the lower limit for daylight of 500 lux and 300 lux, respectively. It also found that the depth of PSALI is different for different orientations. It is greater in the North-East, East, South-East, South-West, West and North-West directions compared to North and South orientations. This is due to the low solar altitude in the morning and afternoon. The research therefore, concludes that these depths may be taken under consideration in the pre-design phase of an office building in order to take maximum advantage of daylight usage in an office interior environment.
Degree Level: Master
Call Number: t NA2794A165D 2006
Kullliyah: Kulliyyah of Architecture and Environmental Design
Programme: Master of Science in Built Environment
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/2610
URL: https://lib.iium.edu.my/mom/services/mom/document/getFile/Vts88G4L73mJQkTjxhXAftUo1LYBchfV20070417153618921
Appears in Collections:KAED Thesis

Files in This Item:
File Description SizeFormat 
t0001090160ABUNURMOHAMMADSHAHRIRNA2794A165D2006_SEC_24.pdf24 pages file257.13 kBAdobe PDFView/Open
t0001090160ABUNURMOHAMMADSHAHRIRNA2794A165D2006_SEC.pdf
  Restricted Access
Full text secured file11.96 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

16
checked on May 18, 2021

Download(s)

10
checked on May 18, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.