Please use this identifier to cite or link to this item: http://studentrepo.iium.edu.my/handle/123456789/2592
Title: The in vivo study of injection moulded 316L stainless steel fracture fixation plate
Authors: Nurul Hafiza binti Mohd Jan
Subject: Injection molding of metals
Year: 2015
Publisher: Kuala Lumpur : International Islamic University Malaysia, 2015
Abstract in English: Metal Injection Moulding (MIM) is a revolutionary new class of medical implant fabrication in orthopaedics. This technology employs natural resources and holds great promises in producing large quantities of metallic parts for prosthetic implant at minimum outlay without compromising its quality. The present study was conducted to compare potential effects of MIM plate for internal fixation in fracture healing in New Zealand White (NZW) rabbits with conventional machining plate (Synthes®) as control. Following research approval by IIUM Ethics Committee (IIUM/305/20/4/10), forty rabbits were used and randomly divided into two groups. All rabbits underwent single transverse mid-shaft tibial fracture surgery and fixation under anaesthesia. The fractures were fixated with either the MIM plate or conventional plate (Synthes®). The monitoring of fracture healing was carried out at week 3, 6, 9, 12 and 26 according to ISO10993-2:2006 & ISO10993-6:2009 standards. The status of bony union was examined by means of plain radiographic assessment, macroscopic observation and, histological evaluation. There were callus formations in both groups. Bony union was evident at week 6 post-operatively, whilst bone remodelling was completed at week 26 as indicated by plain radiograph assessment and macroscopic evaluation. Histological assessment showed that both groups possessed mild to moderate callus bridging at week 3 and week 6, respectively. Complete remodelling of cortical bone was evidenced at week 26. The plate was neither broken nor bent during the study. These findings indicate that the MIM plate has equal potential to hold the fracture as the conventional plate. Therefore, the locally manufactured MIM plate has the potential to be used as an alternative internal fixator for fracture management in orthopaedic considering the value and conservation of natural resources.
Degree Level: Master
Call Number: t TS 243 N974I 2015
Kullliyah: Kulliyyah of Allied Health Sciences
Programme: Master of Health Sciences
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/2592
URL: https://lib.iium.edu.my/mom/services/mom/document/getFile/AuA2ylUO9XF8GmDgkOdt0q8o2SPaMtbE20150723140943475
Appears in Collections:KAHS Thesis

Files in This Item:
File Description SizeFormat 
t11100340961NurulHafiza_SEC_24.pdf24 pages file429.95 kBAdobe PDFView/Open
t11100340961NurulHafiza_SEC.pdf
  Restricted Access
Full text secured file9.53 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

14
checked on May 18, 2021

Download(s)

8
checked on May 18, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.