Please use this identifier to cite or link to this item: http://studentrepo.iium.edu.my/handle/123456789/5250
Title: Study of nonspecific binding of Escherichia. coli 0157:H7 on IgG immobolized on reduced graphene oxide electrodes with linear sweep voltammetry
Authors: Ahmed, Nasteho Ali
Subject: Biosensors
Detectors
Escherichia coli O157:H7
Year: 2019
Publisher: Kuala Lumpur :Kulliyyah of Engineering, International Islamic University Malaysia,2019
Abstract in English: Microorganisms contamination of water is a major problem in the world. Escherichia coli is one of the significant waterborne pathogens which can cause severe health problems. The methods for detection and quantification of pathogens are time consuming, require advanced equipment and extensive procedure which is not applicable to be used in the field. Alternatively, electrochemical immunosensors for pathogen detection are used to overcome issue of specificity thanks to the antigen-antibody complex. However, antigen-antibody interaction suffers from nonspecific binding that can result in false signal response. To understand the effect of nonspecific binding, an electrochemical immunosensor was developed using immunoglobulin G (IgG) antibody not specific to E. coli O157:H7 and the nonspecific binding was analyzed via Linear Sweep Voltammetry (LSV). Screen-printed carbon electrodes (SPCEs) were modified with reduced graphene oxide (rGO/SPCE) for increased surface area for attachment of antibodies. Antibodies were immobilized by carbodiimide-assisted amidation reaction on rGO/SPCE (IgG/rGO/SPCE). Then, LSV was performed at different scan rates for different electrodes of SPCE, GO/SPCE, rGO/SPCE and IgG/rGO/SPCE. From the plot of the scan rate, effective surface area was calculated; rGO/SPCE was found to have the larger effective surface area of 68.5 mm2 in comparison to SPCE with surface area of 21.7 mm2. Additionally, LSV measurements were conducted for different E. coli concentrations where the electrodes with antibody (IgG/rGO/SPCE) were able to distinguish between the highest and lowest E. coli concentration (4 x 108 and 4 x 100 CFU ml-1) whereas electrode without IgG (rGO/SPCE) showed low distinction between highest and lowest E. coli concentration. Furthermore, FESEM images showed higher binding of cells to IgG/rGO/SPCE electrodes while rGO/SPCE electrodes show less attachment of E. coli. These results suggest that nonspecific binding of E. coli towards IgG can provide false signals in electrochemical measurements, and therefore it is necessary to provide appropriate strategies to avoid nonspecific binding that could lead to misinterpretation of measured signal. Future work will reduce nonspecific binding through modification of electrodes with specific antibody towards E. coli and using blocking agents such as bovine serum albumin (BSA).
Degree Level: Master
Call Number: t R 857 B54 A2867S 2019
Kullliyah: Kulliyyah of Engineering
Programme: Department of Biotechnology Engineering
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/5250
Appears in Collections:KOE Thesis

Files in This Item:
File Description SizeFormat 
t11100410008NastehoAliAhmed_SEC_24.pdf24 pages file781.01 kBAdobe PDFView/Open
t11100410008NastehoAliAhmed_SEC.pdf
  Restricted Access
Full text secured file4.22 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

34
checked on May 20, 2021

Download(s)

16
checked on May 20, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.