Please use this identifier to cite or link to this item: http://studentrepo.iium.edu.my/handle/123456789/4693
Title: A multi level inverter integrated with conditioning interface for grid-tied systems
Authors: Shahid, Zeeshan
Subject: Electronics
Electric power systems
Year: 2016
Publisher: Kuala Lumpur : Kulliyyah of Engineering, International Islamic University Malaysia, 2016
Abstract in English: This thesis presents the proposed design, working principle, simulation and experimental details of a transformer-less multilevel grid-tied inverter. Grid connectivity requires DC-to-AC inversion with efficient synchronization, reduced total harmonic distortion (THD), real-time control and monitoring. The generation of multi-level output can reduce harmonic with effective sinusoidal wave generation and increased efficiency; however, it requires more complex control and implementation. This research has applications in terms of integration of renewable energy sources with utility grids in stand-alone or industrial generation as well as in case of DG systems. This research proposes a six-level DC supply using novel switching technique with DC-DC converter, embedded with an element of adaptability choosing if Buck or Boost is required for addressing amplitude synchronization. Other issues with fly-back mitigation, low pass filter design for THD reduction and almost near to pure sine wave generation are addressed. The H-bridge transformer-less inverter is designed with four IGBTs (operated at 20kHz) synchronized pulse width modulation (PWM). Two additional fly-back IGBTs are introduced in H-bridge inverter to mitigate fly-back spike generation. For grid connectivity, a versatile technique of phase and frequency synchronization is proposed by using analog to digital converters (ADCs). The feedback and monitoring control scheme is proposed and tested for any abnormal occurrence on grid side. This enables continuous observation of the performance of inverters in terms of power sharing, synchronization and stability. Simulation results are validated experimentally; discussed and analyzed. The DC-DC supply under synchronized condition has a voltage variation range from 308V to 356V. In the proposed design, the IGBTs are reduced to active five. The maximum efficiency achieved is 99.3% (compared to 98.6% on the market) and the lowest is 98% under 1.8kW load. The use of six level generation (0V - 372V) has reduced THD to 2.4% following the EN-50160 and IEEE-1547 international standards.
Degree Level: Doctoral
Call Number: t TK1001 S525M 2016
Kullliyah: Kulliyyah of Engineering
Programme: Doctor of Philosophy in Engineering
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/4693
URL: https://lib.iium.edu.my/mom/services/mom/document/getFile/UBzxGmZe2G0gDEqQ1wm3JQYLfwRIggdh20160304114858618
Appears in Collections:KOE Thesis

Files in This Item:
File Description SizeFormat 
t11100344007ZeeshanShahid_SEC_24.pdf24 pages file804.83 kBAdobe PDFView/Open
t11100344007ZeeshanShahid_SEC.pdf
  Restricted Access
Full text secured file7.25 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

36
checked on May 18, 2021

Download(s)

14
checked on May 18, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.