Please use this identifier to cite or link to this item: http://studentrepo.iium.edu.my/handle/123456789/4647
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdul Hafiz bin Zakariaen_US
dc.date.accessioned2020-08-20T11:18:03Z-
dc.date.available2020-08-20T11:18:03Z-
dc.date.issued2017-
dc.identifier.urihttp://studentrepo.iium.edu.my/jspui/handle/123456789/4647-
dc.description.abstractRadiation mapping can be used to give information regarding the intensity of radiation at a particular location. Mapping of radiation autonomously using robot as agent will help to prevent harm to human especially when radiation related disaster occur. In this project radiation mapping system consisting of autonomous mobile robot that is equipped with Geiger Muller sensor was developed. A 3D ionizing radiation map is built from the data of the encoder sensor which indicate the location of the mobile robot as well as the radiation data by the Geiger Muller sensor. A grid based algorithm was develop to build the radiation map. The system was tested under several conditions using Cobalt-60 ionizing radiation sources at Malaysia Nuclear Agency indoor radiation facilities. The results shows that the system manage to produce consistent mapping results for repeating experiments with a maximum standard deviation value of 0.9369 µSv/h. This project also evaluated the performance of the Atmel Atmega328 microcontroller under exposure of ionizing radiation Cobalt-60 source. Geant4 software is used to simulate the passage of radiation beams through the Atmel Atmega328 microcontroller model and calculated the estimated absorbed dose rate using Monte Carlo Methods. Microprocessor that is in operation also was tested under the actual ionizing radiation from Cobalt-60 source of with a radiation activity of 0.09 mCi, 0.45 mCi and 2.31 mCi at a distance starting at 20cm and increasing by 20cm until 100cm from the Cobalt-60 source. The test result show that the microcontroller work flawlessly when operating close to source under radiation absorbed dose rate of 28.257 µGy/h. Keywords: Radiation mapping, Autonomous mobile robot, Atmel Atmega328, Geant4,en_US
dc.language.isoenen_US
dc.publisherKuala Lumpur :International Islamic University Malaysia,2017en_US
dc.rightsCopyright International Islamic University Malaysia
dc.subject.lcshRadiation -- Measurementen_US
dc.subject.lcshMobile robotsen_US
dc.titleDevelopment of ionizing radiation mapping roboten_US
dc.typeMaster Thesisen_US
dc.identifier.urlhttps://lib.iium.edu.my/mom/services/mom/document/getFile/D9AywaMgTlzvIsynX8SBwTVI6AnKPUzR20171127155139562-
dc.description.identityt11100380464AbdHafizZakariaen_US
dc.description.identifierThesis : Development of ionizing radiation mapping robot /by Abdul Hafiz bin Zakariaen_US
dc.description.kulliyahKulliyyah of Engineeringen_US
dc.description.programmeMaster of Science in Mechatronicsen_US
dc.description.degreelevelMaster
dc.description.callnumbert QC 795.42 A1352D 2017en_US
dc.description.notesThesis (MSMCT)--International Islamic University Malaysia, 2017.en_US
dc.description.physicaldescriptionxvii, 120 leaves :illustrations ;30cm.en_US
item.openairetypeMaster Thesis-
item.grantfulltextopen-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Collections:KOE Thesis
Files in This Item:
File Description SizeFormat 
t11100380464AbdHafizZakaria_SEC_24.pdf24 pages file480.63 kBAdobe PDFView/Open
t11100380464AbdHafizZakaria_SEC.pdf
  Restricted Access
Full text secured file1.91 MBAdobe PDFView/Open    Request a copy
Show simple item record

Page view(s)

42
checked on May 18, 2021

Download(s)

16
checked on May 18, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.