Title: The Trend of airborne particulates distribution at residential areas in relation to coal power plant in Manjung, Perak
Authors: Muhammad Ihsan Shaharil
Subject: Dust--Environmental aspects
Particles--Environmental aspects
Air--Pollution
Year: 2015
Publisher: Kuala Lumpur : International Islamic University Malaysia, 2015
Abstract in English: Due to the deterioration of air quality in recent years in line with the rapid development, this study is an initiative to provide an overview of the results of the case study and report on the trends of airborne particles distribution at residential areas in relation to distance from coal power plant in Manjung, Perak. Particulate matter from Manjung coal power plant may possibly one of the decreasing health condition factors of the residents’ related to respiratory besides motor vehicles, industrial activities and other sources. An 8-hour airborne sampling by using 7-hole Sampler (for total inhalable dust) and Cyclone Sampler (for respirable dust) was conducted to measure and quantify physical characteristics of airborne particulates in the site study area both indoor and outdoor. Four sampling points (housing at Teluk Rubiah, Lumut, Sitiawan and Ayer Tawar) were determined by the radius distance 5km, 10km, 15km, 20km away respectively from the coal power plant and the direction, considering the meteorological factors. For indoor mass concentration of total inhalable dust, the trend shows that 5km and 10km sampling point recorded 0.3788 mg/m3 and 0.2575 mg/m3, which exceed the standards for good indoor air quality by EPD (0.180 mg/m3) compared to 15km (0.0663 mg/m3) and 20km (0.1515 mg/m3). As for outdoor mass concentration, the percentage of respirable dust towards total inhalable dust at 10km radius sampling point is the highest among the four sites with 97% (others ranging from 38% to 79%), due the other sources nearby like sea-port, ferry terminal to Pangkor, heavy traffic at tourism point and industrial activities. From the findings, it can be concluded that the level of airborne particulates distribution has association with the coal power plant. Although indoor air quality of the resident’s house was influenced by the nearby coal power plant, however the house design and smoking habits also play the role, studies have shown. The outdoor particulate measurement at residential house in Manjung not only determined by the location or distance from the coal power plant, but the results also considering the meteorological factors and other sources around the sampling point.
Degree Level: Master
Call Number: t TD 884.5 M9524T 2015
Kullliyah: Kulliyyah of Architecture and Environmental Design
Programme: Master of Science (Built Environment)
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/2832
URL: https://lib.iium.edu.my/mom/services/mom/document/getFile/vxEMpYApavCvajMu6FPSE8nAcXxphZLY20160219114757161
Appears in Collections:KAED Thesis

Files in This Item:
File Description SizeFormat 
t11100341137MuhammadIhsan_SEC_24.pdf24 pages file237.6 kBAdobe PDFView/Open
t11100341137MuhammadIhsan_SEC.pdf
  Restricted Access
Full text secured file5.71 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

24
checked on May 18, 2021

Download(s)

12
checked on May 18, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.