Title: The effectiveness of passive design strategies for a mosque in Malaysia : |bcase studies of Putra Mosque and Tuanku Mizan Zainal Abidin Mosque
Authors: Tengku Anis Qarihah binti Raja Abdul Kadir
Subject: Mosques -- Designs and plans -- Malaysia
Mosques -- Design and construction -- Malaysia
Architecture, Islamic -- Malaysia
Year: 2015
Publisher: Kuala Lumpur : International Islamic University Malaysia, 2015
Abstract in English: Malaysia has a tropical climate with warm and humid weather all year round. It is usually very hot and humid, especially in the major cities. Malaysia is the best country to study on the passive design strategies in tropical climates. Since the time of our ancestors, buildings had been built characterized by passive design where it focused on a balance between local climate, surrounding areas, functions, appearances and design of the buildings. Passive design strategies can defined as the measures that had been taken to ensure the comfort of the occupant achieved. It must have a closer relationship with its surroundings to achieve a comfortable internal environment with a minimum of resource used. However, in this modern age, most of the building neglected the beauty of passive design strategies and end up relying on active design strategies such as air conditioning systems and others. This research will discuss the importance of passive design strategies and knowing its effectiveness against the user’s comfort, energy efficiency and the visual impact on the user’s point of view. Characteristic of passive design strategies taken from the Malaysian Standard: MS1525. MS1525 is the Code of Practice on Energy Efficiency and use of Renewable Energy for Non-Residential Buildings, which was developed to provide the best practice in energy efficiency for buildings. Two case studies involved are Putra Mosque and Sultan Mizan Zainal Abidin Mosque. Both federal mosques have a different approach to passive design techniques that comparative studies between both cases studies, help to evaluate the effectiveness of passive design strategies and the perception of user’s preferences. Other than that, questionnaires, interviews, field works and data collections conducted as primary data to justify the results. This research will help designers to determine the characteristic of the passive design strategies that effective in giving comfort to people, reducing energy consumption and add beauty to a building as a whole.
Degree Level: Master
Call Number: t NA 6025.6 M4 T292E 2015
Kullliyah: Kulliyyah of Architecture and Environmental Design
Programme: Master of Science in Building Services Engineering
URI: http://studentrepo.iium.edu.my/jspui/handle/123456789/2794
URL: https://lib.iium.edu.my/mom/services/mom/document/getFile/EHz67nZxZ9cnlgZPyOikG1S3LSDIjbvX20160317112530336
Appears in Collections:KAED Thesis

Files in This Item:
File Description SizeFormat 
t11100342713Tg.AnisQarihah_SEC_24.pdf24 pages file672.54 kBAdobe PDFView/Open
t11100342713Tg.AnisQarihah_SEC.pdf
  Restricted Access
Full text secured file14.1 MBAdobe PDFView/Open    Request a copy
Show full item record

Page view(s)

6
checked on May 18, 2021

Download(s)

2
checked on May 18, 2021

Google ScholarTM

Check


Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.