Please use this identifier to cite or link to this item:
http://studentrepo.iium.edu.my/handle/123456789/2630
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Alkhalaf, Haitham | en_US |
dc.date.accessioned | 2020-08-20T10:20:04Z | - |
dc.date.available | 2020-08-20T10:20:04Z | - |
dc.date.issued | 2014 | - |
dc.identifier.uri | http://studentrepo.iium.edu.my/jspui/handle/123456789/2630 | - |
dc.description.abstract | This thesis is an investigation into the performance of Earth-to-Air Heat Exchanger (EAHE) in Malaysian climate. The passive cooling technology, where the ground is used as a heat sink to produce cooler air, is an emerging of area of interest in Malaysia. The aim of this thesis is to find the best ground cover in improving the EAHE proficiency through thermal model using computer simulation. The pipe, which was used in the thermal model, has same parameters of the real pipe which is 3 inches diameter, 50 meters in length, made of PVC, has the velocity of flow air was 1 m/s and buried in a 4-meters depth. The performance of the EAHE was simulated using loam, clay, silty clay, sandy clay loam as back fill material. It was found that sandy soil is the best cover material. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Kuala Lumpur : International Islamic University Malaysia, 2014 | en_US |
dc.rights | Copyright International Islamic University Malaysia | |
dc.subject.lcsh | Air conditioning | en_US |
dc.subject.lcsh | Buildings -- Energy conservation | en_US |
dc.subject.lcsh | Buildings -- Environmental engineering | en_US |
dc.title | Earth-to-air heat exchanger system : a study on the role of ground cover and system validation in Malaysian climate /by Haitham Alkhalaf | en_US |
dc.type | Master Thesis | en_US |
dc.identifier.url | https://lib.iium.edu.my/mom/services/mom/document/getFile/q8gcAiH6IRFtCCBW4DNqnsTiXnyLyAdo20150403160836014 | - |
dc.description.identity | t11100335167AlKhalaf | en_US |
dc.description.identifier | Thesis : Earth-to-air heat exchanger system : a study on the role of ground cover and system validation in Malaysian climate /by Haitham Alkhalaf | en_US |
dc.description.kulliyah | Kulliyyah of Architecture and Environmental Design | en_US |
dc.description.programme | Master of Science (Building Services Engineering) | en_US |
dc.description.degreelevel | Master | en_US |
dc.description.callnumber | t TH 7687.5 A415E 2014 | en_US |
dc.description.notes | Thesis (MSBSE)--International Islamic University Malaysia, 2014 | en_US |
dc.description.physicaldescription | xiv, 69 leaves : ill. ; 30cm. | en_US |
item.openairetype | Master Thesis | - |
item.grantfulltext | open | - |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | KAED Thesis |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
t11100335167AlKhalaf_SEC_24.pdf | 24 pages file | 1.02 MB | Adobe PDF | View/Open |
t11100335167AlKhalaf_SEC.pdf Restricted Access | Full text secured file | 3.21 MB | Adobe PDF | View/Open Request a copy |
Page view(s)
342
checked on May 20, 2021
Download(s)
16
checked on May 20, 2021
Google ScholarTM
Check
Items in this repository are protected by copyright, with all rights reserved, unless otherwise indicated. Please give due acknowledgement and credits to the original authors and IIUM where applicable. No items shall be used for commercialization purposes except with written consent from the author.